DENVER POWER CONDUIT 1
WDID 0600568Water Right Dependency Report · generated from release evidence · 2026-07-29Decreed
344.0 cfs
1 right(s) · senior 1945-05-10
Median reliability
79%
severe: 15%
Observed callers
6
dominant: COMMUNITY DITCH
Served land
0 parcels
$0 assessed
Active signals
3
0 entitlement gap(s)
1 · What it isdecree components and legal genealogy
| Right | Priority | Amount | Uses | Status |
|---|---|---|---|---|
| 0600568-34828.00000 | 1945-05-10 (admin 34828.00000) | 344 cfs | 34P | Absolute and Conditional |
2 · How it has performedbeneficial-use evidence, honestly classified
- water quality composite
- 0.65
3 · What it depends on & who controls its riverobserved call causality + supply support
- COMMUNITY DITCH
- 142.6 day-eq · 121 episodes / 23 seasons · last 2026 · conf 0.98
- S BOULDER BEAR CR DITCH
- 128.8 day-eq · 48 episodes / 20 seasons · last 2026 · conf 0.98
- HOWARD DITCH
- 97.3 day-eq · 20 episodes / 14 seasons · last 2024 · conf 0.98
- LEYNER COTTONWOOD DITCH
- 89.0 day-eq · 71 episodes / 21 seasons · last 2026 · conf 0.98
- MCGINN DITCH
- 73.9 day-eq · 23 episodes / 13 seasons · last 2025 · conf 0.98
- COTTONWOOD DITCH 2
- 58.6 day-eq · 38 episodes / 21 seasons · last 2026 · conf 0.98
- owner evidence
- DENVER WATER BOARD · probable (0.55)
4 · What happens under stressempirical administration replay + season nowcast
- median year
- 79% seasonal reliability
- severe drought (2002-class)
- 15% seasonal reliability
- method
- empirical replay of observed administration by condition class — modeled, not observed
5 · What else is affected — the land under this waterserved parcels with entitlement + conveyance posture (three truths, never collapsed)
| Parcel | Owner (assessor) | Acres | Assessed | Coverage | Entitlement | Deed posture |
|---|
6 · What can impair it — active signalsevery detection on this structure, its rights, and its land
7 · Verify before closingthe transaction-specific evidence checklist
- resolve right ownership
- best evidence is probable — county deed research + company records required
- verify diligence status
- conditional components require a current diligence finding
- confirm administration exposure
- 6 observed senior caller(s); verify current call status with the division office
- professional review
- this report is data intelligence, not a legal or engineering opinion
Evidence basewhat this report rests on — and what it doesn't
- source coverage
- 6/10 sources live — development (seed fallback present)
- sources
- CDSS structures/net-amounts/calls/diversions · OIT parcels (annual, ≤12mo lag) · irrigated lands · satellite ET · court outcomes · company ledgers
- disclaimer
- data intelligence from public + program records; not a legal opinion, engineering report, or title commitment